Description
• (1) OFL100 OTDR
• (1) Power Supply with USB Cable
• (1) SC/APC Adapter
• (1) 8GB SD Card
• (1) Certificate of Conformance
• (1) Quick reference card
• (1) Soft carry case
FEATURES:
• Test and troubleshoot faults in last mile fiber optic links
• Validate installed last mile fiber optic links for compliance to design•
• Small ruggedized package weighing less than 1.1 pounds
• Short learning curve allows the technician to be productive quickly
• Easy to use “single button” interface with “Auto Test” mode
• Optical power meter, stabilized laser source, and visual fault locator included standard with all models
• Free Trace Viewer documentation program
• Link Viewer that provides a linear Pass/Fail analysis
SPECIFICATIONS:
• On-board storage of 8GB
• OTDR Wavelength: 1310/1550nm
• Dynamic Range: 26/24dB
• Event Deadzone: 2.5m
• Attenuation Deadzone: 8m
• Measurement Ranges: 500m, 1km, 2km, 4km, 8km, 16km, 32km, 64km and 100km
• Pulse Widths: 3ns, 5ns, 10ns, 20ns, 30ns, 50ns, 80ns, 160ns, 320ns, 500ns, 800ns,1?s, 2?s, 3?s, 5?s, 8?s, 10?s and 20?s
• Measurement Accuracy: ±(1m + Sample Interval + 0.005% x Test Distance
• Linearity: ?0.05dB/dB
• Loss Resolution: 0.001dB
• Loss Threshold: 0.20dB
• Distance Resolution: 0.001m
• Refractive Index: 1.00000 to 2.00000
• Reflection Accuracy: ±3dB
• File Format: SOR compliant to Telcordia GR196
• Loss Analysis: Four Point & Five Point
• Laser Safety: Class 1M
• Bulkhead: SC/APC (Optional FC Available)
• Trace Update Rate: 3Hz
• Optical Power Meter Wavelength Range: 800nm to 1700nm
• Calibrated Wavelengths: 850nm, 980nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm and 1650nm
• Measurement Range: +26dBm to -50dBm
• Measurement Resolution: 0.01dB
• Measurement Accuracy: ±5%
• Tone Frequencies/Sensing: CW, 270Hz, 330Hz, 1kHz and 2kHz
• Bulkhead: 2.5mm Universal
• Visual Fault Locator Wavelength: 650nm ±20nm
• Output Power: <1mW
• Mode of Operation: CW, 1Hz and 2Hz
• Bulkhead: 2.5mm Universal
• Laser Safety Class: 2
• Stabilized Light Source Wavelength: 1310/1550nm
• Output Power: ?-5dBm
• Power Stability: CW, ±0.5dB/15 minutes after continuous on of 15 minutes
• Bulkhead: SC/APC (Optional FC Available)
• Tone Frequencies: CW, 270Hz, 330Hz, 1kHz and 2kHz
• Optical Loss Testing Wavelength: 1310nm and 1550nm
• Insertion Loss Testing: Integrated OPM and SLS
• RJ45 Sequence Testing Cable Type: Straight and Interleaved (T568)
• Display: 4.3″ 800×400 TFT LCD Touchscreen
• Power Supply: AC to DC 100-240VAC, 50/60Hz
• Power Supply Format: North America
• Battery Lifetime: >12 Hours Continuous Test
• Internal Storage: 8GB (>200,000 Curves)
• Interface: USB Type C, 8GB SD Card
• Operational Temperature: -10°C to +50°C
• Storage Temperature: -40°C to +70°C
• Relative Humidity: 0 to 95% Non-Condensing
The OFL100 OTDR enables the front-line technician to quickly locate loss events in the last mile of the FTTx network. The touchscreen provides an intuitive interface for even newly provisioned technicians so that they can locate loss events such as cut fibers, contaminated or damaged connectors and excessively bent fibers. The Auto Mode allows for the technician to initiate a measurement without adjusting any test parameters. The Expert OTDR Mode provides access to all the features that the savvy OTDR technician demands so that they can refine measurement parameters to be able to troubleshoot the most demanding faults. Results can be displayed using a traditional OTDR trace or linear map with user-selectable Pass/Fail analysis. All events are measured, annotated, saved and exported as an industry-standard SOR file that is compliant to GR196 Telcordia standards. The SOR file can be imported into the Trace Viewing program where analysis can be performed and test results can be saved as a PDF report. The integrated VFL provides a safe level of red laser light to visually locate fiber faults within the OFL100 deadzone. The VFL can be used to confirm continuity of improperly labeled or not labeled fiber optic cables up to approximately 5km. The VFL output is set to ≤1mW which is a Class 2 device that is deemed to be safe by the FDA. The OPM can be used to measure absolute optical power levels as well as allow the technician to perform loss measurements on a fiber link of the device when used in tandem with the integrated stabilized laser source. Full fiber tracing is supported with tone injection and sensing.
Reviews
There are no reviews yet.